performance factory installation foundations building features assembly sequence options/accessories

Remove Roof Intact

Remove Endwall Intact

Lift Building Intact

Truly Relocatable and
Reusable System

Engineered to Meet IBC
Building Code Requirements
Factory-installed panel features

Panels are shipped in
racks and easily unloaded
with forklift

Factory-installed window
in wall panel

Factory-installed skylights
in roof panels

Doors and louvers are
factory-installed in panels

Galvanized steel panels
without insulation or liner

Painted steel panels
without insulation or liner

Factory-installed insulation with
flat galvanized steel liner


Factory-installed insulation
with painted steel liner

Factory-installed insulation
with exposed foil face liner

Factory-installed noncombustible
mineral wool insulation

Factory-drilled holes for "key" together assembly


No Pre-setting of Anchor
Bolts, No Point Loads

Curb Wall Foundation

Existing Slab Foundation

Temporary Baseplate on Dirt

Temporary Baseplate/Earth
Anchor Foundation

Poured Concrete Foundation

Concrete Trench Foundation

Wood Baseplate Foundation

No Metal Building Assembly
Experience Required

Small Crew Installation
4 times faster assembly than conventional buildings because of factory-installed windows, doors and insulation








This building was completed
in FOUR working days!
large building assembly sequence
(click here)
(click here)
small building assembly sequence
(click here)
(click here)
- Galvanized
- Painted Exterior Finish (Either Silicone Polyester or Kynar Coating)
FACTORY-INSTALLED INSULATION:
- R-11 (1-1/2") Premium Rigid Insulation Board w/Foil-Faced Interior
- R-19 (2-1/2") Premium Rigid Insulation Board w/Foil-Faced Interior
- Non-combustible 2" Mineral Wool Insulation
FACTORY-INSTALLED STEEL LINER:
Wall Panels:
Wall Panels:
- None (Aluminum Foil, Vapor Barrier Only)
- Natural (Plain Flat Galvanized Sheet)
- Painted (Stone or Regal White, per Kelly's Color Chart)
- None (Aluminum Foil, Vapor Barrier Only)
- Natural (Plain Flat Galvanized Sheet)
- Painted (Stone or Regal White, per Kelly's Color Chart)
PERSONNEL DOORS:
- 3'0" x 7'0" Hollow Core Conventional Door
- Insulated
- Non-Insulated
- Double Doors: 5'8" x 7'0" Hollow Core Conventional Door
- Insulated
- Non-Insulated
- 18-Gauge Honey Comb Door Leaf
- 16-Gauge Frame
- Primer and Gray Finish Coat of Paint
- Ball Bearing Hinges
- Standard Door Sweep
- Lt. Commercial Lockset and Closer
- Formed Steel Threshold
- Miami-Dade County Hurricane Rated
- UFC 4-010-01 Anti-Terrorism Rated
- Insulated Door Leaf
- Painted to Match Building Color
- HD Lockset or ADA Lever (Schlage or Best)
- Mortise Locksets (Schlage or Best)
- HD ADA Closer
- Weather Stripping
- Exit-Only Panic Hdwe
- HD Panic Hdwe with Outside Lever Entry (Best or Schlage Lock Cylinder)
- Most Other Types of Hardware Available as Special Order
- Widths from 6'-12' Wide Standard (Widths up to 24'W Available)
- Heights from 8' to 16' Standard (Taller Doors Available)
- Light-Duty Non-Slat Continuous Curtain Door
- Insulated or Non-Insulated
- Manual or Electric Operator
- Heavy-Duty Slat Style Roll-Up Door
- Insulated or Non-Insulated
- Manual or Electric Operator
- Miami-Dade County Hurricane Rated Available
LIGHT TRANSMITTING PANELS
- Designate quantity
(Maximum 25% of roof area)
WINDOWS
- Standard 2' Wide x 3' High Sliding Window Factory-Installed
- Field-Installed Windows (Aluminum Single Hung, Special Order)
- Miami-Dade County Hurricane Rated
- UFC 4-101-01 Anti-Terrorism Rated
- 2' x 4' Non-Egress or 3' x 5' Egress
VENTILATION (Factory-Installed)
- A/C Frameout
- Thru-Wall HVAC Frameout
- Wall-Mount HVAC Frameout
- Rooftop Rotary Wind Turbines
- 2' x 2' Fixed Louver w/Screen
- 2' x 2' Fixed Louver w/Gravity Shutter
- 2' x 2' Fixed Louver w/Motorized Shutter
- 2' x 2' Fixed Louver w/Gravity Shutter & 2900 CFM Fan
- Gutters and Downspouts
CUSTOM INTERIORS:








































